To respect copyright laws, request permission by email ( before downloading PDFs.


Marghoub A, Libby J, Babbs C, Pauws E, Fagan MJ, Moazen M. 2018. Predicting calvarial growth in normal and craniosynostotic mice using a computational approach. Journal of Anatomy. 232:440-448. pdf


Libby J, Marghoub A, Johnson D, Khonsari R, Fagan MJ, Moazen M. 2017. Modelling human skull growth: a validated computational model. Journal of The Royal Society Interface. 14:20170202. pdf


Moazen M, Leonidou A, Pagkalos J, Marghoub A, Fagan MJ, Tsiridis E, 2016. Application of far cortical locking technology in periprosthetic femoral fracture fixation: a biomechanical study. The Journal of Arthroplasty. 31:1849-1856. pdf

Ardestani MM, Moazen M, 2016. How human gait responds to muscle impairment in total knee arthroplasty patients: muscular compensations and articular perturbations. Journal of Biomechanics. 49:1620-1633. pdf

Ardestani MM, Ferrigno C, Moazen M, Wimmer MA, 2016. From normal to fast walking: Impact of cadence and stride length on lower extremity joint moments. Gait & Posture. 46:118-125. pdf

Moazen M, Alazmani A, Rafferty K, Liu ZJ, Gustafson J, Cunningham ML, Fagan MJ, Herring SW, 2016. Intracranial pressure changes during mouse development. Journal of Biomechanics. 49:123-126. pdf


Graham SM, Mak JH, Moazen M, Jones AC, Wilcox RK, Tsiridis E, 2015. Periprosthetic femoral fracture fixation – a biomechanical comparison between proximal locking screws and cables. Journal of Orthopaedic Science. 20:875-880. pdf

Moazen M, Peskett E, Babbs C, Pauws E, Fagan MJ, 2015. Mechanical properties of calvarial bones in a mouse model for craniosynostosis. PLoS ONE. 12;10:e0125757. pdf

Ardestani MM, Moazen M, Wenjian Y, Maniei E, Ghomsheh FT, Jin Z, 2015. Contribution of geometric design parameters to knee implant performance: conflicting impact of conformity on kinematics and contact mechanics. The Knee. 22:217-224. pdf

Ardestani MM, Moazen M, Wenjian Y, Maniei E, Jin Z, 2015. Posterior stabilized versus cruciate retaining total knee arthroplasty designs: conformity affects reliability, design impacts sensitivity. Medical Engineering & Physics. 37:350-360. pdf

Ardestani MM, Moazen M, Jin Z, 2015. Sensitivity analysis of human lower extremity joint moments due to changes in gait kinematics. Medical Engineering & Physics. 37:165-174. pdf

Ardestani MM, Moazen M, Chen Z, Zhang J, Jin Z, 2015. A real-time topography of maximum contact pressure distribution at medial tibiofemoral knee implant during gait: application to knee rehabilitation. Neurocomputing. 154:174-188. pdf

Leonidou A, Moazen M, Lepetsos P, Graham SM, Macheras GA, Tsiridis E, 2015. The biomechanical effect of bone quality and fracture topography on locking plate fixation in periprosthetic femoral fractures. Injury. 46:213-217. pdf


Ardestani MM, Moazen M, Jin Z, 2014. Gait Modification and optimization using neural network-genetic algorithm approach: application to knee rehabilitation. Expert Systems with Applications, 41:7466-77. pdf

Moazen M, Mak JH, Etchels LW, Jin Z, Wilcox RK, Jones AC, Tsiridis E, 2014. Periprosthetic femoral – a biomechanical comparison between Vancouver type B1 and B2 fixation methods. The Journal of Arthroplasty, 29:495-500. pdf


Leonidou A, Moazen M, Skrzypiec DM, Graham SM, Pagkalos J, Tsiridis E, 2013. Evaluation of fracture topography and bone quality in periprosthetic femoral fractures: A preliminary radiographic study of consecutive clinical data. Injury, 44: 1799-1804. pdf

Moazen M, Mak JH, Etchels LW, Jin Z, Wilcox RK, Jones AC, Tsiridis E, 2013. The effect of fracture stability on the performance of locking plate fixation in periprosthetic femoral fractures. The Journal of Arthroplasty, 28: 1598-1595. pdf

Moazen M, Mak JH, Jones AC, Jin Z, Wilcox RK, Tsiridis E, 2013. Evaluation of a new approch for modelling the screw-bone interface in a locking plate fixation – a corroboration study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 227: 746-756. pdf

Graham SM, Moazen M, Leonidou A, Tsiridis E, 2013. Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 cases. Journal of Orthopaedic Science, 18: 426-436. pdf

Moazen M, Costantini D, Bruner E, 2013. A sensitivity analysis to the role of fronto-parietal suture in Lacerta bilineata: a preliminary finite element approach. The Anatomical Record, 296: 198-209. pdf


Moazen M, Jones AC, Leonidou A, Jin Z, Wilcox RK, Tsiridis E, 2012. Rigid versus flexible plate fixation for periprosthetic femoral fracture – computer modelling of a clinical case. Medical Engineering & Physics, 34: 1041-1048. pdf


Moazen M, Jones AC, Jin Z, Wilcox RK, Tsiridis E, 2011. Periprosthetic fracture fixation of the femur following total hip arthroplasty: a review of biomechanical testing. Clinical Biomechanics, 26: 13-22. pdf


Costantini D, Alonso ML, Moazen M, Bruner E, 2010. The relationship between cephalic scales and bones in lizards: a preliminary microtomographic survey on three lacertid species. The Anatomical Record, 293: 183-194. pdf


Moazen M, Curtis N, O’Higgins P, Evans SE, Fagan MJ, 2009. Biomechanical assessment of evolutionary changes in the lepidosaurian skull. Proceedings of the National Academy of Science USA, 106: 8273-8277. pdf

Moazen M, Curtis N, O’Higgins P, Jones MEH, Evans SE, Fagan MJ, 2009. Assessment of the role of sutures in a lizard skull- a computer modelling study. Proceedings of the Royal Society, Part B, 276: 39-46. pdf


Moazen M, Curtis N, Evans SE, O’Higgins P, Fagan MJ, 2008. Combined finite element and multibody dynamics analysis of biting in a Uromastyx hardwickii lizard skull. Journal of Anatomy, 213: 499-508. pdf

Curtis N, Kupczik K, O’Higgins P, Moazen M, Fagan MJ, 2008. Predicting skull loading: applying multibody dynamics analysis to a macaque skull. The Anatomical Record, 291: 491-501. pdf

Moazen M, Curtis N, Evans SE, O’Higgins P, Fagan MJ, 2008. Rigid-body analysis of a lizard skull: modelling the skull of Uromastyx hardwickii. Journal of Biomechanics, 41: 1274-1280. pdf